Abstract
An innovative Direct Residual Heat Removal System (DRHRS) is proposed for Pressurized Water Reactor (PWR) in this paper. The new designed parallel DRHRS is different from traditional Passive Residual Heat Removal System (PRHRS), which is connected to steam generation. The thermal hydraulic transient analysis of the new designed DRHRS for CPR1000 has been carried out using the widely accepted safety analysis software RELAP5. The new designed DRHRS is directly connected to the primary loop, which consists of three independent parallel loops, three intermediate cooling circuits and an air loop. The transient behaviors of passive safety system are studied, and design parameter sensitivity analysis is carried out. Results show that during Station Black_Out (SBO) accident, natural circulations are established stably in passive safety system so that core decay is continuously removed from primary loop. And the new designed DRHRS has the capability of removing residual heat to the atmosphere without any external energy input at different surrounding environmental temperature. In emergency, the DRHRS directly remove core decay heat from reactor outlet, and efficiency of residual heat removal is improved. Moreover, reactor power plant maintains safe even if double-ended rupture of a single tube during SBO accident occurs. Thus, the designed DRHRS has great significance for increasing the degree of inherent safety features of CPR1000.