To identify an appropriate neighbourhood case study area, publicly available datasets were assessed for the town of Bicester (Oxfordshire, UK), which included Ordnance Survey Mastermap, Energy Performance Certificate data (EPC) and sub-national energy statistics available at lower layer super output area (LSOA). When the EPC data for Bicester were compared with the sub-national statistics for Bicester, the average difference was found to be ∼800 kWh. This is interesting as EPCs represent dwelling specific but modelled data whereas sub-national datasets represent actual but aggregated data. Superimposing the above datasets, a neighbourhood in southwest Bicester was selected as having the highest percentage of dwellings with energy consumption >300 kWh/m2/yr (EPC), most dwellings in need of wall insulation (EPC), second highest mean total energy consumption (sub-national), and third highest percentage of fuel poor dwellings (sub-national). House-level energy assessment in the selected area using DECoRuM showed that a package based approach comprising fabric and heating system upgrade and solar PVs emerged as the most effective.