Article ID Journal Published Year Pages File Type
810604 Journal of the Mechanical Behavior of Biomedical Materials 2015 10 Pages PDF
Abstract

•We characterized polymerization kinetics and polymerization stress in new, aged, and expired composites.•The syringe dental composites underwent an accelerated aging protocol (Arrhenius model).•The parameters tested changed mainly for the nanofilled and silorane composites.•Silorane composite presents lower stress values among the materials in all conditions.•Aging does not affect stress development in restorative composites.

ObjectivesTo determine the effect of material condition (new, aged, and expired) on the polymerization kinetics and polymerization stress of different classifications of dental composites.Materials and methodsSpecimens were obtained according to the following factors: Composites: (3M ESPE) Filtek P60, Filtek Z250, Filtek Z350XT, and Filtek Silorane; and Material conditions: new, aged, and expired. The syringe composites underwent an accelerated aging protocol (Arrhenius model) representing approximately 9 months of aging. Infrared (IR) spectra were obtained kinetically and were analyzed for: maximum conversion rate (%/s), time into exposure when maximum rate occurred (s), conversion at maximum rate (%), and total conversion (%) at 90 s by comparison of absorption IR peak ratios before and after polymerization. Polymerization was evaluated at the bottom surface of 2.0 mm-thick specimens. Polymerization stress was determined in a tensilometer, inserting the composite between acrylic rods fixed to clamps in a universal test machine and dividing the maximum load recorded by the rods cross-sectional area. Polymerization stress (MPa) was calculated at 300 s. Data were statistically analyzed by two-way ANOVA and Tukey’s post hoc test (α=0.05).ResultsThe majority of the polymerization kinetic parameters were not influenced by the material condition. Silorane composite presented significantly lower conversion rate and lower conversion at the maximum rate when expired (p<0.05). The nanofilled composite (Filtek Z350XT) presented a significantly higher total conversion when aged and expired compared to the new one (p>0.05). In all conditions, Filtek Z350XT and Filtek Silorane presented significantly lower conversion rates (p < 0.05). Filtek Silorane also exhibited the lowest stress, irrespective of the material condition (p<0.05). The polymerization stress was not influenced by the material condition (p>0.05).ConclusionsMost of the kinetic parameters are not influenced by the material condition. Filtek P60 and Filtek Z250 are more stable as both composites present similar polymerization kinetic results, irrespective of the material condition. Silorane composite presents lower stress values among the tested materials in all conditions. Aging does not affect stress development in restorative composites.

Related Topics
Physical Sciences and Engineering Engineering Biomedical Engineering
Authors
, , , , , ,