Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
810662 | Journal of the Mechanical Behavior of Biomedical Materials | 2015 | 10 Pages |
This study evaluated the effects of low-temperature aging on the surface topography, phase transformation, biaxial flexural strength, and structural reliability of a ground Y-TZP ceramic. Disc-shaped specimens were manufactured and divided according to two factors: “grinding” – without grinding (as-sintered, Ctrl), grinding with an extra-fine diamond bur (25 µm Xfine) and coarse diamond bur (181 µm Coarse); and “low-temperature-aging” (absence or presence). Grinding was performed using a contra-angle handpiece under water-cooling. Aging was performed in an autoclave at 134 °C, under 2 bar, over a period of 20 h. Surface topography analysis showed an increase in roughness based on grit-size (Coarse>Xfine>Ctrl), and aging promoted different effects on roughness (Ctrl Ag