Abstract

Failure mode under Hertzian indentation and the behavior on immersion in water of bis-GMA-based composites with HA whiskers or nanoscopic HA powder as filler were evaluated. Failure load decreased with increase in filler loading, but the decrease was smaller for whiskers, which showed a different failure mode both macroscopically and microscopically. Particle-filled composites failed mainly by radial cracking and cone cracking, with some plastic deformation at low filler loading, with fracture into irregular segments. For whisker-filled materials, crack propagation was inhibited by the well-dispersed whiskers by the usual toughening mechanisms; cone cracking was the dominant failure mode, at higher loads than for the powder, and fracture was incomplete. The filler reduced both water-uptake and elution of soluble materials, as expected, but both were lower for the whisker-filled material. Such composites might form the basis of viable materials for dental load-bearing restorations and other applications.

► Incorporation of HA whiskers in resin composites conferred high failure load. ► Cone cracking was the dominant failure mode at higher whisker load. ► Crack propagation of resin composites was inhibited by well-dispersed whiskers. ► Whisker filler reduced both water-uptake and elution of soluble materials.

Related Topics