Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8128231 | Journal of Natural Gas Science and Engineering | 2018 | 31 Pages |
Abstract
The shockwave position is found in the range of 0.3-0.5 of non-dimensional nozzle length. The positions of both shockwave and initiation of condensation are shifted toward the exit side when the nozzle pressure ratio decreases. Reducing the pressure ratio from 0.8 to 0.6 will enhance the dehydration efficiency by about 5%.
Related Topics
Physical Sciences and Engineering
Earth and Planetary Sciences
Earth and Planetary Sciences (General)
Authors
Pouriya H. Niknam, H.R. Mortaheb, B. Mokhtarani,