Article ID Journal Published Year Pages File Type
8128393 Journal of Natural Gas Science and Engineering 2018 22 Pages PDF
Abstract
Process simulations were performed using Aspen Plus software to predict the behaviour of the pilot-scale rig using a model developed based on empirical parameters (i.e., mass transfer coefficient of CO2 through the membrane and permeance), measured in the bench-scale membrane test unit. The results show that CO2 concentrations of up to 14.9% (comparable to CO2 level in coal combustion) can be achieved with 60% EGR, with a 90% CO2 removal efficiency of the membrane units. However, the results generated with the membrane model in which specific permeance values to PDMS were applied, predicted concentrations of CO2 in flue gases up to 9.8% (v/v) for a selective recycle of 60%. The study shows that the S-EGR technique is an effective method that can provide similar conditions to that of a coal-fired power plant for the post-combustion capture system operating on natural gas-fired units, but also highlights the fact that more research is required to find more suitable materials for membranes that optimise the CO2 removal efficiencies from the flue gas.
Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Earth and Planetary Sciences (General)
Authors
, , , , , ,