Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8164680 | Physica C: Superconductivity and its Applications | 2014 | 4 Pages |
Abstract
In order to test the performance of experimental advanced superconducting tokamak (EAST) central solenoid (CS) model coil, which was made by the cable-in-conduit conductor using Nb3Sn strands and a 316Â L stainless steel jacket, a cryogenic experiment system was designed. The experimental results showed that the superconducting magnet was cooled down to 5Â K, which could meet the test requirements successfully. Meanwhile, we measured the pressure drop in CICC of Nb3Sn superconducting magnet under the circulating mode of forced flow cooling which used supercritical helium as coolant compared with the result calculated by the Katheder fraction factor correlation, it showed that calculated pressure drop underestimates the experimental data. We corrected the Katheder correlation and compared with the experimental data, it proved that the corrected correlation is much more suitable for the kind of CICC of Nb3Sn superconducting magnet.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Condensed Matter Physics
Authors
Q.W. Hao, H.J. Liu, Y. Wu, S. Guo,