Abstract
Peking University Neutron Imaging Facility (PKUNIFTY) works on an accelerator-based neutron source with a repetition period of 10Â ms and pulse duration of 0.4Â ms, which has a rather low Cd ratio. To improve the effective Cd ratio and thus improve the detection capability of the facility, energy-filtering neutron imaging was realized with the intensified CCD camera and time-of-flight (TOF) method. Time structure of the pulsed neutron source was firstly simulated with Geant4, and the simulation result was evaluated with experiment. Both simulation and experiment results indicated that fast neutrons and epithermal neutrons were concentrated in the first 0.8Â ms of each pulse period; meanwhile in the period of 0.8-2.0Â ms only thermal neutrons existed. Based on this result, neutron images with and without energy filtering were acquired respectively, and it showed that detection capability of PKUNIFTY was improved with setting the exposure interval as 0.8-2.0Â ms, especially for materials with strong moderating capability.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
Hu Wang, Yubin Zou, Weiwei Wen, Yuanrong Lu, Zhiyu Guo,