For the purpose of selecting the most suitable photomultiplier tubes (PMTs) for the Wide Field of view Cherenkov/fluorescence Telescope Array (WFCTA), we have performed extensive tests on seven models of 25.4 mm PMTs: Hamamatsu R1924A and R7899, Beijing Hamamatsu CR303, CR332A and CR364, and HZC Photonics XP3102 and XP3182. A dedicated test system has been developed to measure the PMT characteristics such as single photo-electron spectrum, gain, linearity, and spatial uniformity of anode output. The XP3182 and CR364 (R7899) tubes both meet the pivotal requirement due to their superior pulse linearity. The PMT test system, techniques used for these measurements, and their results are also reported.