CHICO2 (Compact Heavy Ion COunter), is a large solid-angle, charged-particle detector array developed to provide both θ and Ï angle resolutions matching those of GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array). CHICO2 was successfully tested at the Argonne National Laboratory where it was fielded as an auxiliary detector with GRETINA for γ-ray spectroscopic studies of nuclei using a 252Cf spontaneous fission source, stable beams, and radioactive beams from CARIBU. In field tests of the 72,76Ge beams on a 0.5 mg/cm2208Pb target at the sub-barrier energy, CHICO2 provided charged-particle angle resolutions (FWHM) of 1.55° in θ and 2.47° in Ï. This achieves the design goal for both coordinates assuming a beam-spot size (>3 mm) and the target thickness (>0.5 mg/cm2). The combined angular resolution of GRETINA/CHICO2 resulted in a Doppler-shift corrected energy resolution of 0.60% for 1 MeV coincident de-excitation γ-rays. This is nearly a factor of two improvements in resolution and sensitivity compared to Gammasphere/CHICO. Kinematically-coincident detection of scattered ions by CHICO2 still maintains the mass resolution (ÎM/M) of ~5% that enhanced isolation of scattered weak beams of interest from scattered contaminant beams.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
C.Y. Wu, D. Cline, A. Hayes, R.S. Flight, A.M. Melchionna, C. Zhou, I.Y. Lee, D. Swan, R. Fox, J.T. Anderson,