Article ID Journal Published Year Pages File Type
8172307 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2015 4 Pages PDF
Abstract
A square 3D-Trench electrode Si detector structure is simulated using a 3D TCAD tool. Electrical characteristics including electrostatic potential, electric field, leakage current, and capacitance have been simulated in detail. It has been found in simulations that both leakage current and the voltage to reach the geometry capacitance (full depletion voltage, Vfd) increase with radiation fluence. The geometry capacitance is 99 fF for the standard structure in our study. Detector geometry capacitance׳s dependence on the length and area of the collection column has also been simulated.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , , ,