The results of this study suggest that DDA instrument response depends on the position of the individual neutron detectors and in fact can be split in two modes. The first mode, measured by the back detectors, is not significantly sensitive to the spatial distribution of fissile isotopes and neutron absorbers, but rather reflects the total amount of both contributors as in the cases of symmetrically burned SFAs. In contrary, the second mode, measured by the front detectors, yields certain sensitivity to the orientation of the asymmetrically burned SFA inside the assaying instrument. This study thus provides evidence that the DDA instrument can potentially be utilized as necessary in both ways, i.e. a quick determination of the average SFA characteristics in a single assay, as well as a more detailed characterization involving several DDA observables through assay of the SFA from all of its four sides that can possibly map the burn-up distribution and/or identify diversion or replacement of pins.