Article ID Journal Published Year Pages File Type
8174759 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2014 8 Pages PDF
Abstract
In this study, we designed and manufactured a pulsed multipole magnet for beam injection into the UVSOR-III ring. A sextupole-like magnetic field could be excited when using the multipole magnet. To compensate for the residual field at the center of the magnet caused by manufacturing imprecisions, thin ferrite sheets were used. The injection experiments at UVSOR-III demonstrated multi-turn injections with the pulsed multipole magnet. The injection efficiency was 23% and the electron beam was stored up to the normal operation current of 300 mA. Moreover, we confirmed that oscillations of stored beams caused by beam injection were drastically suppressed compared with conventional pulsed dipole injection.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , , , , , , , ,