Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8175643 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2014 | 8 Pages |
Abstract
For a longitudinal characterization of an ultra-short electron bunch, an rf-deflector cavity is the best resolution technique that can directly convert longitudinal distribution to transverse. This paper describes the principle of longitudinal diagnostics using an rf-deflector cavity, the design details of an rf-deflector cavity and the results of rf-characteristics for a manufactured cavity. The cavity is based on a rectangular two-cell structure operating on standing wave Ï-mode, dipole (TM120) mode at 2856 MHz. We have confirmed using HFSS simulation that this cavity can produce a deflecting voltage of 1.63 MV with an input rf-power of 750 kW. The results of low power rf-measurement of the manufactured cavity show an effective deflecting voltage of 1.00 MV which corresponds to a temporal resolution of 58 fs (rms) (250 fs/mm on the profile monitor) with 750 kW input rf-power, drift length L of 1 m and initial size Ïoff of 230 μm. These results indicate that we have successfully achieved our target: temporal resolution of less than 100 fs with an electron bunch with energy of 4.5 MeV and charge of 100 pC.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
Y. Nishimura, K. Sakaue, M. Nishiyama, T. Takahashi, M. Washio, T. Takatomi, J. Urakawa,