Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8175824 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2014 | 6 Pages |
Abstract
In order to improve the image quality of fast neutron radiography, a converter made of scintillator and wavelength-shifting fibers has been developed. The appropriate parameters of the converter such as fibers arrangement, distance between fibers are optimized theoretically, and manufacture of the converter are also optimized. Fast neutron radiography experiments by 14 MeV neutrons are used to test this converter and kinds of traditional converters. The experiments' results matched the calculations. The novel converter׳s resolution is better than 1 mm and the light output is high.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
Hang Li, Yang Wu, Chao Cao, Heyong Huo, Bin Tang,