Article ID Journal Published Year Pages File Type
8175879 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2014 12 Pages PDF
Abstract
In 2008, the Cornell Electron Storage Ring (CESR) was reconfigured to serve as a test accelerator (CesrTA) for next generation lepton colliders, in particular for the ILC damping ring. A significant part of this program has been the installation of diagnostic devices to measure and quantify the electron cloud effect, a potential limiting factor in these machines. One such device is the Retarding Field Analyzer (RFA), which provides information on the local electron cloud density and energy distribution. Several different styles of RFAs have been designed, tested, and deployed throughout the CESR ring. They have been used to study the growth of the cloud in different beam conditions, and to evaluate the efficacy of different mitigation techniques. This paper will provide an overview of RFA results obtained in a magnetic field free environment.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , , , , , ,