Article ID Journal Published Year Pages File Type
8177559 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2014 4 Pages PDF
Abstract
We have fabricated radiation detectors using p-type indium antimonide crystals grown by liquid phase epitaxy (LPE). The current-voltage curves, energy spectra of alpha particles, and energy resolutions obtained using two different InSb detectors were compared. The alpha-particle energy resolutions were 1.8% at 24 and 42 K, using the LPE-InSb detector with wafer size of 1.0×1.5 mm2.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , ,