Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8179090 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2013 | 4 Pages |
Abstract
A new glass plate (GP) has been developed for a hole-type micropattern gas detector (MPGD). The material of the GP is a crystallized photosensitive etching glass (PEG3C) made by Hoya Corporation. A basic performance test of the hole-type MPGD was carried out using an X-ray beam with Ne-based gas mixtures at 1Â atm. Gains of up to 5Ã103 and 6Ã104 were obtained using a single and a double GP, respectively. An energy resolution of 17% was obtained for 6Â keV X-rays with a single GP. It was also shown that there is little charging-up effect in the GP. In this paper, we report the characteristics of the new hole-type MPGD with a GP made of PEG3C.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
Fuyuki Tokanai, Toru Moriya, Mirei Takeyama, Hirohisa Sakurai, Shuichi Gunji, Takashi Fushie, Hajime Kikuchi, Takayuki Sumiyoshi, Hirioyuki Sugiyama, Teruyuki Okada, Noboru Ohishi, Syunji Kishimoto, Hideki Hamagaki,