Article ID Journal Published Year Pages File Type
8179258 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2013 12 Pages PDF
Abstract
A novel method for direct electronic “fast-timing” lifetime measurements of nuclear excited states via γ-γ coincidences using an array equipped with N∈N equally shaped very fast high-resolution LaBr3(Ce) scintillator detectors is presented. Analogous to the mirror symmetric centroid difference method, the generalized centroid difference method provides two independent “start” and “stop” time spectra obtained by a superposition of the N(N−1)γ-γ time difference spectra of the N detector fast-timing system. The two fast-timing array time spectra correspond to a forward and reverse gating of a specific γ-γ cascade. Provided that the energy response and the electronic time pick-off of the detectors are almost equal, a mean prompt response difference between start and stop events is calibrated and used as a single correction for lifetime determination. These combined fast-timing arrays mean γ-γ time-walk characteristics can be determined for 40keV