												We present a Hybrid Monte-Carlo method (HMCM) for simulating neutron and photon radiographs. HMCM utilizes the combination of a Monte-Carlo particle simulation for calculating incident film radiation and a statistical post-processing routine to simulate film noise. Since the method relies on MCNP for transport calculations, it is easily generalized to most non-destructive evaluation (NDE) simulations. We verify the method's accuracy through ASTM International's E592-99 publication, Standard Guide to Obtainable Equivalent Penetrameter Sensitivity for Radiography of Steel Plates [1]. Potential uses for the method include characterizing alternative radiological sources and simulating NDE radiographs.