Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8209181 | Applied Radiation and Isotopes | 2016 | 21 Pages |
Abstract
In this research gas sealed Multi-Wire Proportional Counter (MWPC) including blades between anode wires and beta particles of 90Sr with 196Â keV mean energy were considered. Ten different gases such as Noble gases mixtures with methane and several other pure gases were studied. In this type of detector, by using Garfield and Maxwell codes and for each of the gases, variation of different parameters such as first Townsend, electron attachment coefficients with variable electric field and their effects on pulse height or collected charge and in turn on Signal to Noise Ratio (SNR) were studied. Also the effect of anode voltage and its diameter and the pressure of gas on the pulse height were studied. Results show that Garfield and Maxwell codes can be used to study and improve the design of other gaseous detectors.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Radiation
Authors
M. Ebrahimi Shohani, S.M. Golgoun, M. Aminipour, A. Shabani, A.R. Mazoochi, R. Maghsoudi Akbari, M. Mohammadzadeh, M.R. Davarpanah, D. Sardari, M. Sadeghi, F. Babapour Mofrad, A. Jafari,