Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8210208 | Applied Radiation and Isotopes | 2014 | 9 Pages |
Abstract
The University of Oklahoma-College of Pharmacy has installed the first Biomarker Generator (BG75) comprising a self-shielded 7.5-MeV proton beam positive ion cyclotron and an aseptic automated chemistry production and quality control module for production of [18F]Fâ and clinical [18F]FDG. Performance, reliability, and safety of the system for the production of “dose on demand” were tested over several months. No-carrier-added [18F]Fâ was obtained through the 18O(p,n)18F nuclear reaction by irradiation (20-40 min) of a >95% enriched [18O]H2O target (280 μl) with a 7.5-MeV proton beam (3.5-5.0 μA). Automated quality control tests were performed on each dose. The HPLC-based analytical methods were validated against USP methods of quality control. [18F]FDG produced by BG75 was tested in a mouse tumor model implanted with H441 human lung adenocarcinoma cells. After initial installment and optimization, the [18F]Fâ production has been consistent since March 2011 with a maximum production of 400 to 450 mCi in a day. The average yield is 0.61 mCi/min and 0.92 mCi/min at 3.8 µA and 5 µA, respectively. The current target window has held up for over 25 weeks against >400 bombardment cycles. [18F]FDG production has been consistent since June 2012 with an average of six doses/day in an automated synthesis mode (RCYâ50%). The release criteria included USP-specified limits for pH, residual solvents (acetonitrile/ethanol), kryptofix, radiochemical purity/identity, and filter integrity test. The entire automated operation generated minimal radiation exposure hazard to the operator and environment. As expected, [18F]FDG produced by BG75 was found to delineate tumor volume in a mouse model of xenograft tumor. In summary, production and quality control of “[18F]FDG dose on demand” have been accomplished in an automated and safe manner by the first Biomarker Generator. The implementation of a cGMP quality system is under way towards the ANDA submission and first clinical use of [18F]FDG produced by BG75.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Radiation
Authors
V. Awasthi, J. Watson, H. Gali, G. Matlock, A. McFarland, J. Bailey, A. Anzellotti,