Abstract
We have developed a dose calculation and planning engine that prepares a set of treatment plans covering a wide range of theoretical clinically feasible gaze angles for a given patient, by precalculating the dose distributions for each gaze angle. By considering different structures and adapting their constraints, the identification of the optimal gaze angle can be realized. With a better understanding of the dose-volume constraints and the development of strategies to react to the trade-offs between considered structures, ATP may lead to a complete automation of the planning process for UM treated with proton therapy.