Abstract
RapidPlan knowledge-based treatment plans were comparable to CP if the patient's OAR-planning target volume geometry was within the range of those included in the models. EG2 results showed that a model including swallowing-muscle and oral-cavity sparing can be applied to patients with only salivary gland sparing. This may allow model library sharing between institutes. Optimal detection of inadequate plans and population of model libraries requires further investigation.