Abstract
Stereotactic body radiation therapy with proton arc and Photon-VMAT generate significantly more conformal high-dose volumes than standard proton SBRT, without loss of coverage of the tumor and with significant sparing of nearby organs, such as chest wall. In addition, both proton arc approaches spare the healthy lung from low-dose radiation relative to photon VMAT. Our data suggest that IMPT-Arc should be developed for clinical use.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Radiation
Authors
Joao PhD, Guan MSc, Tiago MSc, Hanne PhD, Henning MD,