Article ID Journal Published Year Pages File Type
8239759 International Journal of Radiation Oncology*Biology*Physics 2008 8 Pages PDF
Abstract
The predictive value of the dose-volume histogram was confirmed for bleeding, consistent with previously suggested constraints (V50 <55%, V60 <40%, V70 <25%, and V75 <5%). A dose-volume histogram constraint for incontinence can be suggested (V40 <65-70%). Previous abdominal/pelvic surgery correlated with all toxicity types; thus, a modified constraint for bleeding (V70 <15%) can be suggested for patients with a history of abdominal/pelvis surgery, although further validation on a larger population with longer follow-up is needed.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Radiation
Authors
, , , , , , , , , , ,