Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8243577 | International Journal of Radiation Oncology*Biology*Physics | 2007 | 10 Pages |
Abstract
Conclusions: This study validates the use of daily image-guided target localization and alignment using electronic portal imaging of implanted gold seed fiducials as a valuable method to correct for interfraction target motion and to improve precision in the delivery of postprostatectomy radiotherapy.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Radiation
Authors
Daniel C. M.D., Alexander R. M.D., Ph.D., Michael M.S., Michele M.Sc.E.E., Jean Ph.D., Joycelyn M.D., Ph.D., I.-Chow M.D., Katsuto M.D., Mack M.D.,