Article ID Journal Published Year Pages File Type
8247850 International Journal of Radiation Oncology*Biology*Physics 2006 5 Pages PDF
Abstract
Conclusion: A spinal cord PRV generated with a 6-mm margin leads to a 99% probability of maintaining the maximum spinal cord dose below 45 Gy. The application of an on-line setup correction protocol reduces the cord dose by approximately 5 Gy.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Radiation
Authors
, , , , , ,