Abstract
Recombinant human erythropoietin (rhEPO) is a commonly used biopharmaceutical for the treatment of anemia-associated disorders. Epogen; glycosylated erythropoietin (G-EPO) has short half-life and poor stability. Pegylated Epogen (Peg-G-EPO) was introduced to the market to overcome these limitations. The combined effects of pegylation and glycosylation on the stability of Peg-G-EPO was studied. Determination of Peg-G-EPO in the presence of its degradation products was achieved using SE-HPLC. The assay was validated according to ICH guidelines over concentration range of 50.00-320.00 μg/mL (r 0.9999). A mobile phase of 50 mM phosphate buffer (pH 6.5) with 300 mM sodium chloride and 20% ethanol was employed. Isocratic elution was carried out at 0.5 mL/min over run time of 30 min. Peg-G-EPO was found stable towards mechanical agitation only at low concentrations while it was stable towards repeated freeze/thaw; regardless of the concentration. Effect of temperature and pH were also investigated and Peg-G-EPO was found stable within narrow ranges. Results indicated formation of small molecular weight and very high molecular weight aggregates that have been filtered-off the column. Although Peg-G-EPO was found relatively more stable than its non-pegylated but glycosylated version, results indicated the need for careful stability-assessment of Peg-G-EPO.
Related Topics
Life Sciences
Biochemistry, Genetics and Molecular Biology
Biochemistry, Genetics and Molecular Biology (General)
Authors
Heba S. Abed, Medhat A. Al-Ghobashy, Faten A. Fathalla, Maissa Y. Salem,