Article ID Journal Published Year Pages File Type
854244 Procedia Engineering 2016 8 Pages PDF
Abstract
Controlled modulus columns (CMC) for ground improvement are installed using a hollow stem displacement auger to induce lateral soil displacement effect, followed by grout injection. While the method reduces spoils, the excessive lateral soil displacement may damage adjacent structures. Although there has been growing interest in quantifying such effects, only a handful of studies have been attempted. This paper presents the results of a numerical investigation on the CMC installation effect on an existing bridge pile using the three-dimensional finite difference software package FLAC3D. It has been found that when the CMC is long and the existing bridge pile is slender, the pile bending moment and pile lateral movement, induced by the CMC installation effect, can be significant.
Related Topics
Physical Sciences and Engineering Engineering Engineering (General)
Authors
, , , ,