Errors are being made at all levels of training in applying basic principles such as restoring fibula length and screening the syndesmosis intra-operatively. Appropriate placement and selection of hardware is not always being deployed in osteopenic bone resulting in premature failure of fixation and fracture patterns are not being fully appreciated. Patients are undergoing preventable secondary procedures in the operative treatment of ankle fractures.