Abstract
The present results suggest the feasibility of localizing brain electrical sources from iEEG recordings and improving EEG source localization using simultaneous EEG and iEEG recordings to cover the whole brain. The hybrid EEG and iEEG source imaging can assist the clinicians when unequivocal decisions about determining the epileptogenic zone cannot be reached using a single modality.
Related Topics
Life Sciences
Neuroscience
Neurology
Authors
Seyed Amir Hossein Hosseini, Abbas Sohrabpour, Bin He,