Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8699417 | Journal of Endodontics | 2018 | 4 Pages |
Abstract
Under the conditions of this study, all of the instrumentation systems caused apical debris extrusion to some degree. The WaveOne Gold reciprocating system was associated with less debris extrusion in curved root canals compared with the manual technique and the Twisted File Adaptive system although the difference between the WaveOne Gold and Twisted File Adaptive systems was not significant.
Related Topics
Health Sciences
Medicine and Dentistry
Dentistry, Oral Surgery and Medicine
Authors
Daiana MSc, Débora Delai MSc, Carolina Bender MSc, PatrÃcia Maria Polli PhD, Fabiana Saores PhD,