Abstract

This work analyzes and attempts to enhance the accuracy and reproducibility of parametric modeling in the discrete cosine transform (DCT) domain for the estimation of abnormal intra-QRS potentials (AIQP) in signal-averaged electrocardiograms. One hundred sets of white noise with a flat frequency response were introduced to simulate the unpredictable, broadband AIQP when quantitatively analyzing estimation error. Further, a high-frequency AIQP parameter was defined to minimize estimation error caused by the overlap between normal QRS and AIQP in low-frequency DCT coefficients. Seventy-two patients from Taiwan were recruited for the study, comprising 30 patients with ventricular tachycardia (VT) and 42 without VT. Analytical results showed that VT patients had a significant decrease in the estimated AIQP. The global diagnostic performance (area under the receiver operating characteristic curve) of AIQP rose from 73.0% to 84.2% in lead Y, and from 58.3% to 79.1% in lead Z, when the high-frequency range fell from 100% to 80%. The combination of AIQP and ventricular late potentials further enhanced performance to 92.9% (specificity = 90.5%, sensitivity = 90%). Therefore, the significantly reduced AIQP in VT patients, possibly also including dominant unpredictable potentials within the normal QRS complex, may be new promising evidence of ventricular arrhythmias.

Related Topics
Physical Sciences and Engineering Engineering Biomedical Engineering