Article ID Journal Published Year Pages File Type
8792206 Journal of American Association for Pediatric Ophthalmology and Strabismus 2018 11 Pages PDF
Abstract
The double Maddox rod test is often used to measure cyclodeviations and to monitor change over time. The purpose of this study was to estimate test-retest reliability and the amount of cyclodeviation that would be considered real change using 95% limits of agreement. We retrospectively studied 86 clinically stable patients with double Maddox rod measurements 5-175 days apart (median, 69 days). The range of cyclodeviation at the first measurement was 6° incyclodeviation to 15° excyclodeviation. We calculated the half width of the 95% limits of agreement to be 4.7°, which means that a change of ≥5° in cyclodeviation would be considered a real change. The threshold of 5° should be used when assessing change between two measurements made with double Maddox rods.
Related Topics
Health Sciences Medicine and Dentistry Ophthalmology
Authors
, , , , ,