In our case, corrective surgery in a patient with zygomatic implants resulted in an intraorbital hemorrhage, followed by an orbital compression syndrome. Emergency surgery was immediately performed, allowing hematoma drainage and eliminating compression of the intraorbital content. Symptoms quickly resolved and eyesight was not compromised.