Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
8935173 | British Journal of Anaesthesia | 2012 | 4 Pages |
Abstract
We conclude that the needle and local anaesthetic placement using the standard landmark-based approach to the TAP block is inaccurate, and the incidence of peritoneal placement is unacceptably high.
Related Topics
Health Sciences
Medicine and Dentistry
Anesthesiology and Pain Medicine
Authors
G. McDermott, E. Korba, U. Mata, M. Jaigirdar, N. Narayanan, J. Boylan, N. Conlon,