Article ID Journal Published Year Pages File Type
8955850 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2018 25 Pages PDF
Abstract
Analysis was performed using a Synchronous Charge Integration Pulse Shape Discrimination (PSD) algorithm which was applied to data acquired from a mixed fast neutron/gamma radiation field from an AmBe neutron source. The collected pulses were processed offline with the energy and PSD parameters calculated. The quality of the PSD performance was characterised by a common figure of merit (FoM). The best n-γ separation was found by the newer Eljen EJ-276 scintillator with a FoM value of 3.03 ± 0.03 at an energy of 1.5 MeV gamma equivalent. The Amcrys UPS-113NG material achieved a FoM value of 2.60 ± 0.04.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, ,