Article ID Journal Published Year Pages File Type
9335372 Reproductive BioMedicine Online 2005 5 Pages PDF
Abstract
Human spermatozoa can be successfully cryopreserved without the use of cryoprotectants through vitrification at very high warming rates. This is achieved by plunging a small amount of frozen sperm suspension into a warming medium, or a large amount of sperm suspension into an agitated warming medium. The aim of the present study was to compare the motility of human spermatozoa cryopreserved using four different methodologies of cooling and warming: cryoloops, droplets, open-pulled straws and standard open straws. Evaluation of two parameters, motility and viability rate of spermatozoa, suggests that all four methods are suitable for use in assisted reproductive technology. However, only the use of open-pulled straws as well as standard open straws allows the isolation of spermatozoa from liquid nitrogen with low potential risk of microbial contamination during freezing and storage, and is thereby a clean method of vitrification.
Related Topics
Health Sciences Medicine and Dentistry Obstetrics, Gynecology and Women's Health
Authors
, , , , , , , , ,