Abstract
A new model for IOL power calculation was derived based on an optical refractive methodology that breaks away from the conventional art introduced by Fyodorov in the 1960s. A purely refractive algorithm is used to predict the power of the IOL at the time of surgery without the need for axial length and keratometry measurements. This method bypasses some limitations of conventional biometry and shows promise in the post-refractive cataract cases.
Related Topics
Health Sciences Medicine and Dentistry Ophthalmology