A study of the hydromechanical behaviour of a compacted swelling material in the range of suctions comprised between 0 and 40 MPa was performed. This study has required the development of two kinds of suction controlled oedometer devices based on two different suction control techniques. In the range of suctions higher than 8.5 MPa, the saturated salt solutions method was used and a new oedometer using this suction control technique was developed. For suctions lower than 8.5 MPa an osmotic oedometer was used. Despite the differences between the applied suction components (matric and total), the correlation between the two methods was verified for the tested material. The second part of the paper presents a set of oedometer tests conducted under various suctions. The effect of the applied suction on the hydromechanical parameters was studied. First, two swelling phases were highlighted: a low swelling phase above a suction of 4 MPa and a high swelling one below this value. These phases were considered as being related to the microstructure of compacted swelling clays. Secondly, it was shown that the slopes of the elastic part and of the plastic part of the consolidation curves were not influenced significantly by the applied suctions. In opposition, the preconsolidation pressure is affected by the decrease of the applied suctions even in the low swelling phase. Such a behaviour could be explained by the effects of wetting on the microstructure.