Article ID Journal Published Year Pages File Type
95591 Forensic Science International 2014 7 Pages PDF
Abstract

The recovery of low molecular weight oxygenates in fire debris samples is severely compromised by the use of heated passive headspace concentration with an activated charcoal strip, as outlined in ASTM E-1412. The term “oxygenate” is defined herein as a small, polar, organic molecule, such as acetone, methanol, ethanol, or isopropanol, which can be employed as an ignitable liquid and referred to in the ASTM classification scheme as the “oxygenated solvents” class. Although a well accepted technique, the higher affinity of activated carbon strips for heavy molecular weight products over low molecular weight products and hydrocarbons over oxygenated products, it does not allow for efficient recovery of oxygenates such as low molecular weight alcohols and acetone. The objective of this study was to develop and evaluate a novel method for the enhanced recovery of oxygenates from fire debris samples. By optimizing conditions of the heated passive headspace technique, the utilization of zeolites allowed for the successful collection and concentration of oxygenates. The results demonstrated that zeolites increased the recovery of oxygenates by at least 1.5-fold compared to the activated carbon strip and may complement the currently used extraction technique.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , ,