Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
9632563 | Hydrometallurgy | 2005 | 8 Pages |
Abstract
In a three-stage batch continuous extraction test, >Â 99% Cd and 0.4% Zn were extracted. The loaded organic solution contained 3.87 g/L Cd and only 12 ppm Zn. In a two-stage batch continuous scrubbing test, all the co-extracted Zn was removed with the scrubbed organic containing <Â 1 ppm Zn. Nearly 99% of cadmium was stripped in two batch contacts with 20 g/L sulphuric acid. Excellent separation of Cd and Zn can be achieved in three stages of extraction, two stages of scrubbing and two stage of stripping with this synergistic SX system.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Chemical Engineering (General)
Authors
Davood Moradkhani, Mark Urbani, Chu Yong Cheng, Masood Askari, Daruosh Bastani,