Abstract
The authors secondly investigated the height of released anthropogenic heat from the HVAC system based on a field survey and a database of HVAC systems provided by certain journals. From these investigations, it is presented that the type of HVAC system and the height of released anthropogenic heat vary with the building scale. Finally, an investigation of urban geometric figures was conducted using GIS data from Tokyo and Fukuoka in Japan. The vertical distribution features of both the roughness volume density and the building wall area density were classified according to the gross ratio of building volume.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Renewable Energy, Sustainability and the Environment
Authors
Aya Hagishima, Jun Tanimoto,