Article ID Journal Published Year Pages File Type
9681181 Desalination 2005 7 Pages PDF
Abstract
Energy recovery device is now an essential apparatus for SWRO plants, and it can be classified into two categories: the turbine type and the positive displacement PD type. The PD type contributes a higher energy recovery efficiency (ERE) (>90%) than the turbine type (50%-75%) and becomes a more promising and competitive technology of the field. The experiment simulates the PD energy recovery process under a lower test pressure/HP concentrate pressure (∼0.6 MPa). Mainly, the dynamic characteristics and effect of HP concentrate pressure on the ERE of the unit are inspected and analyzed.
Related Topics
Physical Sciences and Engineering Chemical Engineering Filtration and Separation