Abstract
The authors newly propose and investigate two types of carbon dioxide recovering SOFC/GT combined power generation systems in which a gas turbine with carbon dioxide recycle or water vapor injection is adopted as the bottoming cycle. In these systems, fuel gas is first introduced to a SOFC, and its exhaust fuel gas is afterburned by pure oxygen. Carbon dioxide or water vapor is also injected into the combustor to reduce the combustion gas temperature. The obtained combustion gas, which is composed of only carbon dioxide and water vapor, is introduced to a gas turbine in the bottoming cycle. The exhaust gas of the gas turbine preheats the injection gas, and then, carbon dioxide is separated by only cooling and water condensation. It is made clear that the overall efficiency of the system with carbon dioxide recycle reaches 63.87% (HHV) or 70.88% (LHV), and that of the system with water vapor injection reaches 65.00% (HHV) or 72.13% (LHV). These values are sufficiently high, indicating that the proposed systems are worth further research and development.