Article ID Journal Published Year Pages File Type
9704017 International Journal of Fatigue 2005 8 Pages PDF
Abstract
The effect of thread pitch (coarse and fine threads) on fatigue life of ISO bolts within the range of 10≤D≤24 mm (D=outside diameter) and American Unified bolts within the range of 7/16″≤D≤1″ was studied. The experimental results showed that ISO standard coarse threaded bolts have a higher fatigue life than the fine threaded bolts. For unified bolts, however, when the comparison is made on the basis of core diameter, coarse threaded bolts are superior to the fine ones, whereas on a nominal based comparison, both coarse and fine threaded bolts exhibit the same loading capacity. The results also indicated that for the same core stress, the fatigue life of both ISO and unified bolts, except for 1″ unified bolts, decreases as the nominal diameter increases within the range tested. For 1″ unified bolts, the fatigue life increases with the increase of nominal diameter.
Related Topics
Physical Sciences and Engineering Engineering Mechanical Engineering
Authors
, , ,