Article ID Journal Published Year Pages File Type
9755011 Microchemical Journal 2005 4 Pages PDF
Abstract
Fly ash samples of cement works were analysed using slurry nebulization inductively coupled plasma atomic emission spectrometric (ICP-AES). Because of the influence of the experimental factors on the signal intensity, the optimal conditions of the analysis circumstances were determined. Control analyses (wet digestion followed by ICP-AES, and XRF of dry powders (pressed pellets)) were also carried out to compare the results. Based on the result, it was concluded that the slurry nebulization method using slurry standard of same type reference material for calibration can be applied for rapid but less precise (RSD 5-10%) determination of the elements in fly ash.
Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry