Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
9845918 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2005 | 6 Pages |
Abstract
The energy resolution and non-proportionality of the light yield versus γ-ray energy of pure CsI scintillators directly coupled to Large Area Avalanche Photodiodes (LAAPDs) and cooled down to the liquid nitrogen temperatures have been studied. A very high light output above 1 00 000 ph/MeV was measured. One of the samples showed nearly proportional light yield response versus energy of γ-rays yielding energy resolution of 4.3±0.2% for 662 keV γ-rays from a 137Cs source. The intrinsic resolution of the crystals versus energy of γ-rays has been estimated by measurements of the number of primary electron-hole pairs generated in LAAPD by scintillation light. Inspection of the γ-ray-induced emission spectra of tested samples allows discussing different shapes of non-proportionality curves observed with various samples of CsI.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
M. MoszyÅski, M. Balcerzyk, W. Czarnacki, M. Kapusta, W. Klamra, P. Schotanus, A. Syntfeld, M. Szawlowski, V. Kozlov,